EOL ISFS Staff
ISFS Lead Scientist: Steve Oncley
Engineers: Chris Rodon, Gary Granger, Isabel Suhr
Technicians: Dan Buonome, Tony Wiese
Data Managers: Jacquie Witte, Matt Paulus
Related Documentation
netCDF File Conventions: https://www.eol.ucar.edu/content/isfs-netcdf-files
ISFS Guides: https://www.eol.ucar.edu/content/isfs-guides
Realtime Preliminary Plots
NCHARTS: CFACT preliminary data, winds in instrument coordinates plots
CFACT ISFS Data Tables and Plots
Instrument Description Summary
The standard 5-min ISFS products include measurements from the following sensors:
Sensor | Short Name* | Manufacturer | Samples/s |
---|---|---|---|
Disdrometer | ott | Parsivel2 | 1 |
Radiometer | nr01 | 4-component Hukseflux NR01 | 0.2 |
Soils | Tsoil, Qsoil, Gsoil, Tau63 | NCAR 4-level Tsoil, Meter EC-5 Qsoil, REBS HFT Gsoil, and Hukseflux TP01 Tau63 |
0.2 |
Snow depth | |||
Visibility (T, RH, Rain rate parameters) | T.cs, RH.cs, Vis.cs | Campbell Scientific CS125 | |
3D sonic anemometer | sonic | Campbell Scientific CSAT3** (C125) | 20 |
H2O/CO2 Open-path InfraRed Gas Analyser (IRGA) | irga | Campbell Scientific (combination of EC100 and EC150) | 20 |
Hygrothermometer | T, RH | NCAR SHT85 | 1 |
Nanobarometer | P | Paroscientific 6000 | 13 |
*Abbreviated short name that is used throughout this report.
**With the optional CSAT3A sonic anemometer head to couple with the IRGA EC150.
A subset of these sensor products (those sensors in bold) are in the high rate dataset.
Site Description and Sensors
11 flux towers were operated throughout the Heber City valley region, Utah. Towers comprised of two 30 m multilevel flux profile Rohns, i.e. supersites, and ten single low-level flux stations.
Refer to the table below for site locations and sensor configurations around Heber City. Note, site names in brackets are the short names used in the netCDF files.
Most of the sites were similarly instrumented. At the top of each site's tower are:
- Sonic anemometer and open-path infrared H2O/CO2 gas analyzer (Campbell CSAT3AW/EC150) for turbulent fluxes,
- Slow-response temperature/humidity sensor (NCAR SHT)
All soil sensors (NCAR 4-level Tsoil, Meter EC-5 Qsoil, REBS HFT Gsoil, and Hukseflux TP01 Csoil) were buried at 0--5cm layer near the base of towered sites.
Radiometers are mounted separately on darkhorse tripods and are considered near-surface measurements.
Ott disdrometers are also set-up separately and close to the base of the towers.
Site | Lat | Lon | Tower hgt (m) | Sensor.[Heights] |
---|---|---|---|---|
Provo River Supersite (prs) | 40.528118 | -111.445836 | 32 |
P.2m |
Deer Creek Supersite (dcs) | 40.490101 | -111.464737 | 32 | P.2m TRH.[1m, 2m, 3m, 7m, 17m, 32m] sonic.[1m, 2m, 3m, 7m, 17m, 32m] irga.[1m, 2m, 3m, 7m, 17m, 32m] nr01 all soils |
Upper Provo (up) | 40.55752 | -111.42852 | 3 | P.3m TRH.[0.5m, 2m] sonic.3m irga.3m nr01 ott.1m all soils snow depth |
Midway Lane (mw) | 40.508516 | -111.437739 | 5 | P.5m TRH.[0.5m, 2m, cs.1m] Vis.cs.1m sonic.5m irga.5m nr01 ott.1m all soils snow depth |
Lake Creek (lc) | 40.493671 | -111.32765 | 5 | P.5m TRH.[0.5m, 2m] sonic.5m irga.5m nr01 ott.1m all soils snow depth |
Center Creek (cc) | 40.466344 | -111.335625 | 3 | P.3m TRH.[0.5m, 2m] sonic.3m irga.3m nr01 ott.1m all soils snow depth |
Daniel Canyon (dc) | 40.459124 | -111.37758 | TBD (3 or 5) | P TRH.[0.5m, 2m, cs.1m] Vis.cs.1m sonic irga nr01 ott.1m all soils snow depth |
South Pivot (sp) | 40.481611 | -111.437426 | 3 | P.3m TRH.[0.5m, 2m, cs.1m] Vis.cs.1m sonic.3m irga.3m nr01.3m ott.1m all soils snow depth |
Soldier Hollow (sh) | 40.483202 | -111.487092 | 3 | P.3m TRH.[0.5m, 2m, cs.1m] Vis.cs.1m sonic.3m irga.3m nr01.3m ott.1m all soils snow depth |
Pine Creek (pc) | 40.543386 | -111.490119 | 3 | P.3m TRH.[0.5m, 2m] sonic.3m irga.3m nr01.3m ott.1m all soils snow depth |
Memorial Hill (mh) | 40.516918 | -111.461368 | 3 | P.3m TRH.[0.5m, 2m, cs.1m] Vis.cs.1m sonic.3m irga.3m nr01.3m ott.1m all soils |
Dataset Documentation Requirements